Assessment Year 2017
Principal Product Grey & Ductile Iron Casting
NAICS 333911: Pump and Pumping Equipment Manufacturing
SIC 3321: Gray and Ductile Iron Foundries
Sales Range $10
M
to 50
M
# of Employees 125
Plant Area 182,000
ft2
Annual Production 4,500
ton
Production Hrs. Annual 3,000
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $504,870 7,569,722
kWh
Electricity Demand $237,904 27,243
kW-mo/yr
Electricity Fees $35,711 -
Natural Gas $93,670 18,063
MMBtu
Waste Disposal Costs
Water Usage $14,572 200,000
Tgal
TOTAL YEARLY COSTS $886,727
RECOMMENDED SAVINGS* $77,985 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
01 2.7135: Install occupancy sensors $2,287 $1,245 $1,615
24,065
kWh
$672
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $823 $800 $745
11,104
kWh
- - $78
03 2.7142: Utilize higher efficiency lamps and/or ballasts $19,337 $24,875 $15,128
225,452
kWh
$4,209
-
kW-mo/yr
- -
04 2.4221: Install compressor air intakes in coolest locations $1,488 $302 $1,200
17,879
kWh
$288
-
kW-mo/yr
- -
05 2.7221: Lower temperature during the winter season and vice-versa $7,422 - - - $7,422
-
MMBtu
-
06 2.6211: Conserve energy by efficient use of vending machines $459 $690 $389
5,803
kWh
$70
-
kW-mo/yr
- -
07 2.4314: Use synthetic lubricant $26,785 $47,960 $20,689
308,337
kWh
$6,096
-
kW-mo/yr
- -
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $8,484 $3,000 $6,298
93,862
kWh
$2,186
-
kW-mo/yr
- -
09 2.6218: Turn off equipment when not in use $131 - - - $131
-
MMBtu
-
10 2.2211: Use optimum temperature $9,226 - $9,226
137,500
kWh
- - -
11 2.2511: Insulate bare equipment $1,543 $504 - - $1,543
-
MMBtu
-
TOTAL RECOMMENDED $77,985 $79,376 $55,291
824,002
kWh
$13,521
-
kW-mo/yr
$9,096
-
MMBtu
$78
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs