Assessment Year | 2016 |
---|---|
Principal Product | Cheese, dairy products |
NAICS | 311513: Cheese Manufacturing |
SIC | 2022: Natural, Processed, and Imitation Cheese |
Sales Range | $100 M to 500M |
# of Employees | 160 |
Plant Area |
145,300
ft2
|
Annual Production | 70,000
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,989,463 | 32,237,689 |
kWh
|
$0.062 |
Electricity Demand | $722,604 | 55,702 |
kW-mo/yr
|
$12.97 |
Electricity Fees | $16,773 | - |
|
- |
Natural Gas | $1,269,679 | 300,031 |
MMBtu
|
$4.23 |
TOTAL YEARLY COSTS | $3,998,519 | |||
RECOMMENDED SAVINGS* | $382,389 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,783 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3112: Store heated/ cooled water for use during peak demand periods | $286,874 | $438,150 | - |
$199,896
-
kW-mo/yr
|
$86,978 | - | |
02 | 3.2176: Increase use of automation | $76,440 | $5,500 | - | - | - | $76,440 | |
03 | 2.2135: Repair and eliminate steam leaks | $7,438 | $1,560 |
$5,771
95,536
kWh
|
$1,667
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,649 | $2,000 |
$3,611
58,531
kWh
|
$1,038
-
kW-mo/yr
|
- | - | |
05 | 2.3132: Recharge batteries on during off-peak demand periods | $2,197 | - | - | - | $2,197 | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,696 | $7,212 |
$2,696
43,691
kWh
|
- | - | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,095 | $735 |
$1,602
25,965
kWh
|
$493
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $382,389 | $455,157 |
$13,680
223,723
kWh
|
$203,094
-
kW-mo/yr
|
$89,175 | $76,440 | ||
TOTAL IMPLEMENTED | $14,783 | $10,772 |
$12,078
197,758
kWh
|
$2,705
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs