ITAC Assessment: WM0083
ITAC logo
ITAC Assessment: WM0083
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Plastic Containers Blow Molding
NAICS 326160: Plastics Bottle Manufacturing
SIC 3085: Plastics Bottles
Sales Range $50
M
to 100
M
# of Employees 300
Plant Area 180,000
ft2
Annual Production 40,000,000
lb
Production Hrs. Annual 8,568
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,376,726 21,783,639
kWh
Electricity Demand $467,458 39,327
kW-mo/yr
Electricity Fees $129,254 -
Natural Gas $27,818 4,280
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $153,059 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $44,170

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
01 2.4113: Install motor voltage controller on lightly loaded motors $61,468 $22,995 $61,468
972,590
kWh
- -
02 2.4221: Install compressor air intakes in coolest locations $34,888 $8,785 $27,614
436,934
kWh
$7,274
-
kW-mo/yr
-
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $27,491 $7,200 $21,762
344,335
kWh
$5,729
-
kW-mo/yr
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $13,901 $15,200 $13,602
215,228
kWh
$299
-
kW-mo/yr
-
05 2.2511: Insulate bare equipment $12,261 $1,680 $9,705
153,562
kWh
$2,555
-
kW-mo/yr
-
06 2.7135: Install occupancy sensors $1,673 $1,425 $1,673
26,476
kWh
- -
07 2.7111: Reduce illumination to minimum necessary levels $1,105 $2,490 $947
18,153
kWh
- $158
08 2.6211: Conserve energy by efficient use of vending machines $273 $695 $273
4,313
kWh
- -
TOTAL RECOMMENDED $153,059 $60,470 $137,044
2,171,591
kWh
$15,857
-
kW-mo/yr
$158
TOTAL IMPLEMENTED $44,170 $26,315 $37,984
604,192
kWh
$6,028
-
kW-mo/yr
$158
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs