Assessment Year | 2016 |
---|---|
Principal Product | Plastic Containers Blow Molding |
NAICS | 326160: Plastics Bottle Manufacturing |
SIC | 3085: Plastics Bottles |
Sales Range | $50 M to 100M |
# of Employees | 300 |
Plant Area |
180,000
ft2
|
Annual Production | 40,000,000
lb
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,376,726 | 21,783,639 |
kWh
|
$0.063 |
Electricity Demand | $467,458 | 39,327 |
kW-mo/yr
|
$11.89 |
Electricity Fees | $129,254 | - |
|
- |
Natural Gas | $27,818 | 4,280 |
MMBtu
|
$6.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $153,059 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $44,170 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.4113: Install motor voltage controller on lightly loaded motors | $61,468 | $22,995 |
$61,468
972,590
kWh
|
- | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $34,888 | $8,785 |
$27,614
436,934
kWh
|
$7,274
-
kW-mo/yr
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $27,491 | $7,200 |
$21,762
344,335
kWh
|
$5,729
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,901 | $15,200 |
$13,602
215,228
kWh
|
$299
-
kW-mo/yr
|
- | |
05 | 2.2511: Insulate bare equipment | $12,261 | $1,680 |
$9,705
153,562
kWh
|
$2,555
-
kW-mo/yr
|
- | |
06 | 2.7135: Install occupancy sensors | $1,673 | $1,425 |
$1,673
26,476
kWh
|
- | - | |
07 | 2.7111: Reduce illumination to minimum necessary levels | $1,105 | $2,490 |
$947
18,153
kWh
|
- | $158 | |
08 | 2.6211: Conserve energy by efficient use of vending machines | $273 | $695 |
$273
4,313
kWh
|
- | - | |
TOTAL RECOMMENDED | $153,059 | $60,470 |
$137,044
2,171,591
kWh
|
$15,857
-
kW-mo/yr
|
$158 | ||
TOTAL IMPLEMENTED | $44,170 | $26,315 |
$37,984
604,192
kWh
|
$6,028
-
kW-mo/yr
|
$158 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs