ITAC Assessment: WM0065
ITAC logo
ITAC Assessment: WM0065
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2015
Principal Product rubber molded products
NAICS 326291: Rubber Product Manufacturing for Mechanical Use
SIC 3262: Vitreous China Table and Kitchen Articles
Sales Range $10
M
to 50
M
# of Employees 300
Plant Area 120,000
ft2
Annual Production 112,000,000
pieces
Production Hrs. Annual 8,568
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $554,635 9,223,864
kWh
Electricity Demand $223,478 16,740
kW-mo/yr
Natural Gas $222,063 41,680
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $62,888 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7232: Replace existing hvac unit with high efficiency model $23,093 $64,540 - - $23,093
-
MMBtu
02 2.4234: Cool compressor air intake with heat exchanger $14,101 $7,500 $5,210
86,664
kWh
- $8,891
-
MMBtu
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $10,202 $22,500 $7,065
117,495
kWh
$3,137
-
kW-mo/yr
-
04 2.4314: Use synthetic lubricant $7,132 $2,146 $7,132
118,614
kWh
- -
05 2.2136: Install / repair insulation on steam lines $2,778 $426 - - $2,778
-
MMBtu
06 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $2,598 $6,000 $1,559
25,925
kWh
$1,039
-
kW-mo/yr
-
07 2.7447: Install vinyl strip / high speed / air curtain doors $1,310 $588 - - $1,310
-
MMBtu
08 2.7135: Install occupancy sensors $905 $160 $694
11,532
kWh
$212
-
kW-mo/yr
-
09 2.7134: Use photocell controls $465 $1,035 $465
7,726
kWh
- -
10 2.7135: Install occupancy sensors $304 $536 $233
3,870
kWh
$71
-
kW-mo/yr
-
TOTAL RECOMMENDED $62,888 $105,431 $22,358
371,826
kWh
$4,458
-
kW-mo/yr
$36,072
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs