Assessment Year | 2014 |
---|---|
Principal Product | Architectural Doors |
NAICS | 321911: Wood Window and Door Manufacturing |
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 173 |
Plant Area |
700,000
ft2
|
Annual Production | 130,000
units
|
Production Hrs. Annual | 4,200
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $532,123 | 8,147,681 |
kWh
|
$0.065 |
Electricity Demand | $187,856 | 23,482 |
kW-mo/yr
|
$8.00 |
Electricity Fees | $(-16,649.0) | - |
|
- |
Natural Gas | $748,932 | 112,139 |
MMBtu
|
$6.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $80,621 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,492 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $21,391 | $35,000 | - | - | - |
$21,391
-
MMBtu
|
|
02 | 2.2437: Recover waste heat from equipment | $10,441 | $4,500 | - | - | - |
$10,441
-
MMBtu
|
|
03 | 2.2511: Insulate bare equipment | $133 | $122 | - | - | - |
$133
-
MMBtu
|
|
04 | 2.3134: Shift from daytime to nighttime operation | $2,200 | - | - | - | $2,200 | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,235 | $2,200 |
$6,235
95,487
kWh
|
- | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $4,046 | $302 |
$3,233
49,504
kWh
|
$813
-
kW-mo/yr
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,492 | $1,470 |
$2,972
47,515
kWh
|
$520
-
kW-mo/yr
|
- | - | |
08 | 2.7134: Use photocell controls | $2,825 | $1,125 |
$2,201
33,864
kWh
|
$624
-
kW-mo/yr
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,273 | $9,911 |
$11,113
170,976
kWh
|
$3,160
-
kW-mo/yr
|
- | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,633 | $10,068 |
$7,505
115,424
kWh
|
$2,128
-
kW-mo/yr
|
- | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,180 | $7,175 |
$3,580
54,829
kWh
|
$600
-
kW-mo/yr
|
- | - | |
12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,772 | $7,640 |
$1,772
31,870
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $80,621 | $79,513 |
$38,611
599,469
kWh
|
$7,845
-
kW-mo/yr
|
$2,200 |
$31,965
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,492 | $1,470 |
$2,972
47,515
kWh
|
$520
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs