ITAC Assessment: WM0004
ITAC logo
ITAC Assessment: WM0004
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2012
Principal Product Forgings and Machining
NAICS 332111: Iron and Steel Forging
SIC 3462: Iron and Steel Forgings
Sales Range $50
M
to 100
M
# of Employees 154
Plant Area 380,000
ft2
Annual Production 8,000
ton
Production Hrs. Annual 2,800
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $226,451 3,801,568
kWh
Electricity Demand $132,869 12,210
kW-mo/yr
Electricity Fees $26,031 -
Natural Gas $858,000 156,000
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $58,541 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $27,037

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.2511: Insulate bare equipment $798 $433 - - $798
-
MMBtu
02 2.2414: Use waste heat from hot flue gases to preheat $26,871 $100,000 - - $26,871
-
MMBtu
03 2.2514: Cover open tanks $1,078 $700 - - $1,078
-
MMBtu
04 2.2414: Use waste heat from hot flue gases to preheat $5,511 $1,000 - - $5,511
-
MMBtu
05 2.7142: Utilize higher efficiency lamps and/or ballasts $17,175 $39,950 $11,212
188,116
kWh
$5,963
-
kW-mo/yr
-
06 2.7134: Use photocell controls $3,555 $4,750 $3,555
50,893
kWh
- -
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,280 $750 $2,236
37,512
kWh
$1,044
-
kW-mo/yr
-
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $273 $660 $273
4,573
kWh
- -
TOTAL RECOMMENDED $58,541 $148,243 $17,275
281,094
kWh
$7,008
-
kW-mo/yr
$34,258
-
MMBtu
TOTAL IMPLEMENTED $27,037 $42,793 $13,720
230,201
kWh
$7,008
-
kW-mo/yr
$6,309
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs