Assessment Year 2005
Principal Product Cardboard boxes
NAICS 322130: Paperboard Mills
SIC 2631: Paperboard Mills
Sales Range $10
M
to 50
M
# of Employees 80
Plant Area 189,000
ft2
Annual Production 1,700,000
lb
Production Hrs. Annual 6,000
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $159,605 4,966,600
kWh
Electricity Demand $89,316 11,707
kW-mo/yr
Natural Gas $429,698 60,173
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $188,567 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $21,118

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat $162,672 $360,000 $183,060
5,400,000
kWh
$86,940
-
kW-mo/yr
$(-107,328.0)
-
MMBtu
02 2.7142: Utilize higher efficiency lamps and/or ballasts $14,256 $32,760 $9,668
285,180
kWh
$4,588
-
kW-mo/yr
-
03 2.7221: Lower temperature during the winter season and vice-versa $3,320 $360 - - $3,320
-
MMBtu
04 2.1123: Install automatic stack damper $2,655 $3,400 $2,655
78,330
kWh
- -
05 2.3131: Reschedule plant operations or reduce load to avoid peaks $2,165 - - $2,165
-
kW-mo/yr
-
06 2.4221: Install compressor air intakes in coolest locations $1,800 $1,280 $1,180
34,813
kWh
$620
-
kW-mo/yr
-
07 2.2426: Use waste heat from flue gases to heat space conditioning air $1,135 $1,500 - - $1,135
-
MMBtu
08 2.7124: Make a practice of turning off lights when not needed $322 $150 $322
9,511
kWh
- -
09 2.3132: Recharge batteries on during off-peak demand periods $242 $200 - $242
-
kW-mo/yr
-
TOTAL RECOMMENDED $188,567 $399,650 $196,885
5,807,834
kWh
$94,555
-
kW-mo/yr
$(-102,873.0)
-
MMBtu
TOTAL IMPLEMENTED $21,118 $34,820 $9,668
285,180
kWh
$6,995
-
kW-mo/yr
$4,455
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs