Assessment Year | 2004 |
---|---|
Principal Product | Steel Tubing |
NAICS | 331210: Iron and Steel Pipe and Tube Manufacturing from Purchased Steel |
SIC | 3317: Steel Pipe and Tubes |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
120,000
ft2
|
Annual Production | 45,000
ton
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $116,354 | 4,019,200 |
kWh
|
$0.029 |
Electricity Demand | $83,711 | 11,520 |
kW-mo/yr
|
$7.27 |
Electricity Fees | $12,458 | - |
|
- |
Natural Gas | $35,611 | 4,514 |
MMBtu
|
$7.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $107,836 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,846 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.6124: Burn waste oil for heat | $73,937 | $36,000 |
$(-1,841.0)
(-60,375)
kWh
|
- |
$25,778
-
MMBtu
|
- |
$50,000
-
gal
|
|
02 | 3.4114: Replace city water with recycled water via cooling tower | $15,807 | $21,000 |
$(-2,730.0)
(-89,520)
kWh
|
$(-1,374.0)
-
kW-mo/yr
|
- |
$19,911
-
Tgal
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,856 | $8,856 |
$5,893
193,218
kWh
|
$2,963
-
kW-mo/yr
|
- | - | - | |
04 | 2.7135: Install occupancy sensors | $5,082 | $2,944 |
$3,381
110,872
kWh
|
$1,701
-
kW-mo/yr
|
- | - | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,557 | $4,280 |
$1,557
51,036
kWh
|
- | - | - | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $1,148 | - |
$764
25,065
kWh
|
$384
-
kW-mo/yr
|
- | - | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $1,141 | $640 |
$732
23,993
kWh
|
$409
-
kW-mo/yr
|
- | - | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $308 | $776 |
$154
5,035
kWh
|
$154
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $107,836 | $74,496 |
$7,910
259,324
kWh
|
$4,237
-
kW-mo/yr
|
$25,778
-
MMBtu
|
$19,911
-
Tgal
|
$50,000
-
gal
|
||
TOTAL IMPLEMENTED | $3,846 | $4,920 |
$3,053
100,094
kWh
|
$793
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs