Assessment Year | 2004 |
---|---|
Principal Product | Lighting Fixtures |
NAICS | 335129: Other Lighting Equipment Manufacturing |
SIC | 3645: Residential Electric Lighting Fixtures |
Sales Range | $10 M to 50M |
# of Employees | 450 |
Plant Area |
450,000
ft2
|
Annual Production | 280,000
pieces
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $183,829 | 5,404,400 |
kWh
|
$0.034 |
Electricity Demand | $164,135 | 15,794 |
kW-mo/yr
|
$10.39 |
Electricity Fees | $63,072 | - |
|
- |
Natural Gas | $247,312 | 36,967 |
MMBtu
|
$6.69 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $51,155 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 3.4111: Use closed cycle process to minimize waste water production | $30,420 | $36,000 |
$(-2,500.0)
(-70,028)
kWh
|
- | - | - |
$33,570
-
Tgal
|
$(-650.0) | |
02 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $8,389 | $14,000 |
$8,389
234,990
kWh
|
- | - | - | - | - | |
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $3,916 | $8,000 |
$1,723
48,233
kWh
|
$2,193
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.3132: Recharge batteries on during off-peak demand periods | $4,136 | $1,800 | - |
$3,414
-
kW-mo/yr
|
$722 | - | - | - | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,319 | $500 | - | - | - |
$2,319
-
MMBtu
|
- | - | |
06 | 2.4224: Upgrade controls on compressors | $808 | $2,500 |
$808
22,659
kWh
|
- | - | - | - | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $798 | $840 |
$286
8,012
kWh
|
$512
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $369 | $438 |
$150
4,197
kWh
|
$219
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $51,155 | $64,078 |
$8,856
248,063
kWh
|
$6,338
-
kW-mo/yr
|
$722 |
$2,319
-
MMBtu
|
$33,570
-
Tgal
|
$(-650.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs