| Assessment Year | 2003 |
|---|---|
| Principal Product | Light Towers |
| NAICS | 335121: Residential Electric Lighting Fixture Manufacturing |
| SIC | 3645: Residential Electric Lighting Fixtures |
| Sales Range | $10 M to 50M |
| # of Employees | 105 |
| Plant Area |
50,000
ft2
|
| Annual Production | 7,000
pieces
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $18,924 | 475,960 |
kWh
|
$0.040 |
| Electricity Demand | $14,621 | 1,837 |
kW-mo/yr
|
$7.96 |
| Electricity Fees | $2,427 | - |
|
- |
| Natural Gas | $29,632 | 32,934 |
MMBtu
|
$0.90 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,783 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $7,805 | $11,000 | - | - |
$7,805
-
MMBtu
|
- | - | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $3,965 | $800 | - | - |
$3,965
-
MMBtu
|
- | - | |
| 03 | 3.3132: Use reverse osmosis to concentrate material | $3,333 | $8,000 | - | - | - |
$3,333
-
Tgal
|
- | |
| 04 | 3.7137: Replace cloth rags with paper towels | $1,413 | - | - | - | - | - | $1,413 | |
| 05 | 2.3132: Recharge batteries on during off-peak demand periods | $936 | $200 | - |
$936
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $331 | $740 |
$188
4,481
kWh
|
$143
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $17,783 | $20,740 |
$188
4,481
kWh
|
$1,079
-
kW-mo/yr
|
$11,770
-
MMBtu
|
$3,333
-
Tgal
|
$1,413 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings | |||