Assessment Year 2002
Principal Product Forgings
NAICS
n/a
SIC 3462: Iron and Steel Forgings
Sales Range $10
M
to 50
M
# of Employees 230
Plant Area 175,000
ft2
Annual Production 4,000,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $796,499 27,261,255
kWh
Electricity Demand $563,841 88,643
kW-mo/yr
Electricity Fees $85,686 -
Natural Gas $52,203 60,003
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $65,937 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $514

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.2426: Use waste heat from flue gases to heat space conditioning air $49,518 $23,000 - - $49,518
-
MMBtu
02 2.7135: Install occupancy sensors $11,200 $25,000 $5,203
168,390
kWh
$5,997
-
kW-mo/yr
-
03 2.7135: Install occupancy sensors $3,559 $2,900 $2,489
80,562
kWh
$1,070
-
kW-mo/yr
-
04 2.4221: Install compressor air intakes in coolest locations $1,146 $1,280 $722
23,371
kWh
$424
-
kW-mo/yr
-
05 2.7135: Install occupancy sensors $514 $150 $347
11,232
kWh
$167
-
kW-mo/yr
-
TOTAL RECOMMENDED $65,937 $52,330 $8,761
283,555
kWh
$7,658
-
kW-mo/yr
$49,518
-
MMBtu
TOTAL IMPLEMENTED $514 $150 $347
11,232
kWh
$167
-
kW-mo/yr
-
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs