Assessment Year 2002
Principal Product Envelopes
NAICS
n/a
SIC 2677: Envelopes
Sales Range $1
M
to 5
M
# of Employees 160
Plant Area 300,000
ft2
Annual Production 7,200,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $185,704 5,802,264
kWh
Electricity Demand $132,713 13,738
kW-mo/yr
Electricity Fees $24,565 -
Natural Gas $70,353 8,426
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $54,886 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $49,805

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.7221: Lower temperature during the winter season and vice-versa $15,331 $2,200 - - $15,331
-
MMBtu
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $9,921 $15,527 $6,505
203,280
kWh
$3,416
-
kW-mo/yr
- -
03 2.7135: Install occupancy sensors $6,222 $9,800 $3,187
99,582
kWh
$3,035
-
kW-mo/yr
- -
04 2.7144: Install spectral reflectors / delamp $5,203 - $3,599
112,460
kWh
$1,604
-
kW-mo/yr
- -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $6,879 $1,996 $4,655
145,470
kWh
$2,224
-
kW-mo/yr
- -
06 2.7243: Improve air circulation with destratification fans / other methods $4,308 $8,000 $(-517.0)
(-15,400)
kWh
- $4,825
-
MMBtu
-
07 3.7137: Replace cloth rags with paper towels $3,427 - - - - $3,427
08 2.4221: Install compressor air intakes in coolest locations $1,941 $740 $1,273
39,787
kWh
$668
-
kW-mo/yr
- -
09 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,654 $6,100 $1,654
49,236
kWh
- - -
TOTAL RECOMMENDED $54,886 $44,363 $20,356
634,415
kWh
$10,947
-
kW-mo/yr
$20,156
-
MMBtu
$3,427
TOTAL IMPLEMENTED $49,805 $38,263 $18,702
585,179
kWh
$10,947
-
kW-mo/yr
$20,156
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs