Assessment Year | 2001 |
---|---|
Principal Product | Printed Plastic Packaging |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 75 |
Plant Area |
30,000
ft2
|
Annual Production | 3,600,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $51,364 | 1,577,203 |
kWh
|
$0.033 |
Electricity Demand | $31,944 | 3,612 |
kW-mo/yr
|
$8.84 |
Electricity Fees | $5,628 | - |
|
- |
Natural Gas | $50,718 | 8,330 |
MMBtu
|
$6.09 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,164 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.8142: Distill contaminated solvents for reuse | $19,159 | $14,000 | n/a | - | - | - | - |
$28,706
-
gal
|
$(-2,368.0)
-
lb
|
$(-7,179.0) | - |
02 | 3.4114: Replace city water with recycled water via cooling tower | $10,173 | $19,500 | n/a |
$(-515.0)
(-14,976)
kWh
|
$(-280.0)
-
kW-mo/yr
|
- |
$10,968
-
Tgal
|
- | - | - | - |
03 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $9,162 | $11,500 | n/a | - | - |
$9,162
-
MMBtu
|
- | - | - | - | - |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,714 | $7,393 | n/a |
$1,218
35,388
kWh
|
$496
-
kW-mo/yr
|
- | - | - | - | - | - |
05 | 2.7135: Install occupancy sensors | $147 | $75 | n/a |
$147
4,263
kWh
|
- | - | - | - | - | - | - |
06 | 3.7131: Use a rag recycle service | $1,404 | - | n/a | - | - | - | - | - | - | - | $1,404 |
07 | 2.4221: Install compressor air intakes in coolest locations | $820 | $640 | n/a |
$583
16,955
kWh
|
$237
-
kW-mo/yr
|
- | - | - | - | - | - |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $585 | $403 | n/a |
$428
12,433
kWh
|
$157
-
kW-mo/yr
|
- | - | - | - | - | - |
TOTAL RECOMMENDED | $43,164 | $53,511 |
$1,861
54,063
kWh
|
$610
-
kW-mo/yr
|
$9,162
-
MMBtu
|
$10,968
-
Tgal
|
$28,706
-
gal
|
$(-2,368.0)
-
lb
|
$(-7,179.0) | $1,404 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs