| Assessment Year | 2001 |
|---|---|
| Principal Product | Culture and Natural Extracts |
| NAICS |
n/a
|
| SIC | 2099: Food Preparations, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
55,956
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,400
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $202,882 | 6,654,969 |
kWh
|
$0.030 |
| Electricity Demand | $124,645 | 14,210 |
kW-mo/yr
|
$8.77 |
| Electricity Fees | $23,748 | - |
|
- |
| Natural Gas | $120,289 | 22,233 |
MMBtu
|
$5.41 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $48,014 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $122 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $20,043 | - | - | - | - | $20,043 | |
| 02 | 2.2621: Modify refrigeration system to operate at a lower pressure | $17,182 | $51,500 |
$11,338
352,123
kWh
|
$5,844
-
kW-mo/yr
|
- | - | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $4,793 | $10,000 | - | - |
$4,793
-
MMBtu
|
- | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,072 | $945 |
$1,637
50,827
kWh
|
$435
-
kW-mo/yr
|
- | - | |
| 05 | 3.6192: Use a less expensive method of waste removal | $1,543 | - | - | - | - | $1,543 | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,457 | $7,101 |
$1,020
31,676
kWh
|
$437
-
kW-mo/yr
|
- | - | |
| 07 | 2.7135: Install occupancy sensors | $579 | $200 |
$579
17,971
kWh
|
- | - | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $122 | - |
$87
2,707
kWh
|
$35
-
kW-mo/yr
|
- | - | |
| 09 | 2.4221: Install compressor air intakes in coolest locations | $223 | $640 |
$97
3,012
kWh
|
$126
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $48,014 | $70,386 |
$14,758
458,316
kWh
|
$6,877
-
kW-mo/yr
|
$4,793
-
MMBtu
|
$21,586 | ||
| TOTAL IMPLEMENTED | $122 | - |
$87
2,707
kWh
|
$35
-
kW-mo/yr
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs