Assessment Year | 1999 |
---|---|
Principal Product | Custom Fabricated Metal Products |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
104,000
ft2
|
Annual Production | 2,500,000
lb
|
Production Hrs. Annual | 4,950
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $64,669 | 2,104,924 |
kWh
|
$0.031 |
Electricity Demand | $52,346 | 6,086 |
kW-mo/yr
|
$8.60 |
Electricity Fees | $6,981 | - |
|
- |
Natural Gas | $4,084 | 685 |
MMBtu
|
$5.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,592 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,014 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $9,153 | $30,618 |
$4,581
141,266
kWh
|
$4,572
-
kW-mo/yr
|
- | - | - | - | - | - | |
02 | 2.8121: Apply for tax-free status for energy purchases | $3,971 | - | - | - | - | - | - | - | $3,971 | - | |
03 | 3.8142: Distill contaminated solvents for reuse | $2,819 | $6,000 | - | - | - |
$1,320
-
gal
|
$(-407.0)
-
lb
|
$(-792.0) | - | $2,698 | |
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,051 | - |
$1,094
33,705
kWh
|
$957
-
kW-mo/yr
|
- | - | - | - | - | - | |
05 | 2.2437: Recover waste heat from equipment | $1,340 | $2,000 | - | - |
$1,340
-
MMBtu
|
- | - | - | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $542 | $740 |
$362
11,137
kWh
|
$180
-
kW-mo/yr
|
- | - | - | - | - | - | |
07 | 2.7135: Install occupancy sensors | $470 | $150 |
$470
14,361
kWh
|
- | - | - | - | - | - | - | |
08 | 2.8112: Combine utility meters | $246 | $200 | - | - | - | - | - | - | $246 | - | |
TOTAL RECOMMENDED | $20,592 | $39,708 |
$6,507
200,469
kWh
|
$5,709
-
kW-mo/yr
|
$1,340
-
MMBtu
|
$1,320
-
gal
|
$(-407.0)
-
lb
|
$(-792.0) | $4,217 | $2,698 | ||
TOTAL IMPLEMENTED | $13,014 | $32,768 |
$6,145
189,332
kWh
|
$5,529
-
kW-mo/yr
|
$1,340
-
MMBtu
|
- | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs