Assessment Year | 1997 |
---|---|
Principal Product | Wallcoverings |
NAICS |
n/a
|
SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 41 |
Plant Area |
28,000
ft2
|
Annual Production | 48,000,000
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $29,627 | 991,208 |
kWh
|
$0.030 |
Electricity Demand | $15,059 | 2,716 |
kW-mo/yr
|
$5.54 |
Electricity Fees | $420 | - |
|
- |
Natural Gas | $23,359 | 5,646 |
MMBtu
|
$4.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,140 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $31,361 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.126: Install sensors to detect defects | $30,000 | $36,750 | - | - | - | - | $30,000 | |
02 | 4.321: Optimize production lot sizes and inventories | $1,631 | - | - | - | - | - | $1,631 | |
03 | 2.2437: Recover waste heat from equipment | $1,100 | $150 | - | - |
$1,100
-
MMBtu
|
- | - | |
04 | 2.7261: Install timers and/or thermostats | $787 | $400 | - | - |
$787
-
MMBtu
|
- | - | |
05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $261 | - | - | - | - | $261 | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $261 | - |
$205
6,448
kWh
|
$56
-
kW-mo/yr
|
- | - | - | |
07 | 2.7135: Install occupancy sensors | $100 | $150 |
$100
3,224
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $34,140 | $37,450 |
$305
9,672
kWh
|
$56
-
kW-mo/yr
|
$1,887
-
MMBtu
|
$261 | $31,631 | ||
TOTAL IMPLEMENTED | $31,361 | $36,900 | - | - |
$1,100
-
MMBtu
|
$261 | $30,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs