| Assessment Year | 1996 |
|---|---|
| Principal Product | Industrial Brushes |
| NAICS |
n/a
|
| SIC | 3991: Brooms and Brushes |
| Sales Range | $5 M to 10M |
| # of Employees | 80 |
| Plant Area |
60,000
ft2
|
| Annual Production | 8,000,000
pieces
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $25,021 | 401,817 |
kWh
|
$0.062 |
| Electricity Demand | $11,313 | 1,293 |
kW-mo/yr
|
$8.75 |
| Electricity Fees | $234 | - |
|
- |
| Natural Gas | $15,481 | 3,439 |
MMBtu
|
$4.50 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,833 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,653 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $2,808 | $600 | - | - | - |
$2,808
-
MMBtu
|
- | |
| 02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,948 | $2,800 |
$1,152
37,808
kWh
|
$2,182
-
kW-mo/yr
|
- |
$(-1,386.0)
-
MMBtu
|
- | |
| 03 | 2.7243: Improve air circulation with destratification fans / other methods | $1,559 | $1,550 |
$(-44.0)
(-1,465)
kWh
|
- | - |
$1,603
-
MMBtu
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,194 | $1,800 |
$636
20,809
kWh
|
$558
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $156 | $383 | - |
$156
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.1132: Repair faulty louvers and dampers | $964 | $1,100 | - | - | - |
$964
-
MMBtu
|
- | |
| 07 | 3.5242: Recover metals from spent solutions and recycle | $590 | - | - | - | - | - |
$590
-
lb
|
|
| 08 | 2.8121: Apply for tax-free status for energy purchases | $342 | - | - | - | $342 | - | - | |
| 09 | 3.5217: Reuse / recycle/ sell paper products | $180 | - | - | - | - | - |
$180
-
lb
|
|
| 10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $92 | - |
$92
2,931
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $9,833 | $8,233 |
$1,836
60,083
kWh
|
$2,896
-
kW-mo/yr
|
$342 |
$3,989
-
MMBtu
|
$770
-
lb
|
||
| TOTAL IMPLEMENTED | $5,653 | $3,950 |
$684
22,275
kWh
|
$558
-
kW-mo/yr
|
- |
$4,411
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs