ITAC Assessment: WI0265
ITAC logo
ITAC Assessment: WI0265
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Medical and Surgical Devices
NAICS
n/a
SIC 3069: Fabricated Rubber Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 200
Plant Area 100,000
ft2
Annual Production 3,000
units
Production Hrs. Annual 4,675
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $230,811 4,550,410
kWh
Electricity Demand $84,043 10,755
kW-mo/yr
Electricity Fees $2,239 -
Natural Gas $12,447 2,637
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $68,314 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $41,075

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Water Disposal Savings
01 2.1311: Replace electrically-operated equipment with fossil fuel equipment $35,546 $60,000 $16,388
531,946
kWh
$29,868
-
kW-mo/yr
- $(-10,710.0)
-
MMBtu
-
02 2.8121: Apply for tax-free status for energy purchases $10,889 - - - $10,889 - -
03 2.1311: Replace electrically-operated equipment with fossil fuel equipment $4,667 $8,000 $3,405
110,492
kWh
$3,490
-
kW-mo/yr
- $(-2,228.0)
-
MMBtu
-
04 2.7251: Reduce air conditioning load by evaporating water from roof $6,626 $27,600 $5,179
168,230
kWh
$4,309
-
kW-mo/yr
- - $(-2,862.0)
-
Tgal
05 3.3122: Use filtration, centrifuging to remove contaminants $3,490 $6,500 - - - - $3,490
-
Tgal
06 2.7261: Install timers and/or thermostats $2,039 $6,400 - - - $2,039
-
MMBtu
-
07 3.4115: Recover and reuse cooling water $1,750 $6,000 - - - - $1,750
-
Tgal
08 2.2621: Modify refrigeration system to operate at a lower pressure $954 $4,000 $462
14,947
kWh
$492
-
kW-mo/yr
- - -
09 2.6218: Turn off equipment when not in use $1,135 - $1,135
50,410
kWh
- - - -
10 2.3134: Shift from daytime to nighttime operation $718 - - $718
-
kW-mo/yr
- - -
11 2.3131: Reschedule plant operations or reduce load to avoid peaks $500 $2,000 $270
8,792
kWh
$230
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $68,314 $120,500 $26,839
884,817
kWh
$39,107
-
kW-mo/yr
$10,889 $(-10,899.0)
-
MMBtu
$2,378
-
Tgal
TOTAL IMPLEMENTED $41,075 $72,900 $16,388
531,946
kWh
$29,868
-
kW-mo/yr
- $(-8,671.0)
-
MMBtu
$3,490
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs