Assessment Year | 1996 |
---|---|
Principal Product | Basketball boards, rims, and mounting system |
NAICS |
n/a
|
SIC | 3949: Sporting and Athletic Goods, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 240 |
Plant Area |
124,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 3,744
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $162,083 | 2,798,945 |
kWh
|
$0.058 |
Electricity Demand | $70,172 | 8,033 |
kW-mo/yr
|
$8.74 |
Electricity Fees | $(-1,151.0) | - |
|
- |
Natural Gas | $135,095 | 32,077 |
MMBtu
|
$4.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,748 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,646 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $13,545 | - | - | - | $13,545 | - | - | |
02 | 2.6232: Install set-back timers | $11,567 | $2,400 | - | - | - |
$11,567
-
MMBtu
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,821 | - |
$1,656
52,755
kWh
|
$1,165
-
kW-mo/yr
|
- | - | - | |
04 | 3.6192: Use a less expensive method of waste removal | $1,280 | - | - | - | - | - |
$1,280
-
lb
|
|
05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $828 | - | - |
$828
-
kW-mo/yr
|
- | - | - | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $437 | $700 | - | - | - |
$437
-
MMBtu
|
- | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $270 | - |
$123
4,103
kWh
|
$147
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $30,748 | $3,100 |
$1,779
56,858
kWh
|
$2,140
-
kW-mo/yr
|
$13,545 |
$12,004
-
MMBtu
|
$1,280
-
lb
|
||
TOTAL IMPLEMENTED | $17,646 | - |
$1,656
52,755
kWh
|
$1,165
-
kW-mo/yr
|
$13,545 | - |
$1,280
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs