| Assessment Year | 1995 |
|---|---|
| Principal Product | Lighting Fixtures |
| NAICS |
n/a
|
| SIC | 3646: Commercial, Industrial, and Institutional Electric Lighting Fixtures |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
55,000
ft2
|
| Annual Production | 130,000
pieces
|
| Production Hrs. Annual | 2,550
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $31,620 | 419,109 |
kWh
|
$0.075 |
| Natural Gas | $18,019 | 4,506 |
MMBtu
|
$4.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $10,740 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,501 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7221: Lower temperature during the winter season and vice-versa | $6,790 | $880 | - |
$6,790
-
MMBtu
|
|
| 02 | 2.7243: Improve air circulation with destratification fans / other methods | $2,075 | $3,720 | - |
$2,075
-
MMBtu
|
|
| 03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,028 | $1,850 | - |
$1,028
-
MMBtu
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $473 | $210 |
$473
6,155
kWh
|
- | |
| 05 | 2.7124: Make a practice of turning off lights when not needed | $208 | $160 |
$208
2,638
kWh
|
- | |
| 06 | 2.7135: Install occupancy sensors | $166 | $75 |
$166
2,345
kWh
|
- | |
| TOTAL RECOMMENDED | $10,740 | $6,895 |
$847
11,138
kWh
|
$9,893
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,501 | $2,060 |
$473
6,155
kWh
|
$1,028
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs