| Assessment Year | 2006 |
|---|---|
| Principal Product | Fabricated Rebars |
| NAICS | 332312: Fabricated Structural Metal Manufacturing |
| SIC | 3449: Miscellaneous Structural Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
12,500
ft2
|
| Annual Production | 36,000
ton
|
| Production Hrs. Annual | 3,612
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $15,516 | 2,478 |
kWh
|
$6.26 |
| Electricity Demand | $3,713 | 415 |
kW-mo/yr
|
$8.95 |
| Natural Gas | $5,265 | 1,067 |
MMBtu
|
$4.93 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $35,360 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $30,310 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,410 | $625 |
$3,910
15,842
kWh
|
$1,500
-
kW-mo/yr
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,256 | - |
$1,858
23,839
kWh
|
$398
-
kW-mo/yr
|
- | |
| 03 | 2.7135: Install occupancy sensors | $90 | $135 |
$90
1,160
kWh
|
- | - | |
| 04 | 2.7124: Make a practice of turning off lights when not needed | $20,890 | - |
$20,890
268,585
kWh
|
- | - | |
| 05 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $5,050 | $6,882 |
$5,050
64,812
kWh
|
- | - | |
| 06 | 2.8121: Apply for tax-free status for energy purchases | $1,664 | $832 | - | - | $1,664 | |
| TOTAL RECOMMENDED | $35,360 | $8,474 |
$31,798
374,238
kWh
|
$1,898
-
kW-mo/yr
|
$1,664 | ||
| TOTAL IMPLEMENTED | $30,310 | $1,592 |
$26,748
309,426
kWh
|
$1,898
-
kW-mo/yr
|
$1,664 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs