Assessment Year | 1995 |
---|---|
Principal Product | Labels,Decals |
NAICS |
n/a
|
SIC | 2759: Commercial Printing, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 320 |
Plant Area |
88,700
ft2
|
Annual Production | 6,000,000
thousand feet
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $247,892 | 5,538,394 |
kWh
|
$0.045 |
Natural Gas | $32,765 | 6,488 |
MMBtu
|
$5.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,333 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,085 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.8113: Purchase gas directly from a contract gas supplier | $6,229 | $500 | - | - | $6,229 | |
02 | 2.2437: Recover waste heat from equipment | $4,025 | $300 | - |
$4,025
-
MMBtu
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,265 | $640 |
$1,265
28,136
kWh
|
- | - | |
04 | 2.7221: Lower temperature during the winter season and vice-versa | $1,795 | $400 | - |
$1,795
-
MMBtu
|
- | |
05 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $1,019 | $2,000 |
$1,019
38,687
kWh
|
- | - | |
TOTAL RECOMMENDED | $14,333 | $3,840 |
$2,284
66,823
kWh
|
$5,820
-
MMBtu
|
$6,229 | ||
TOTAL IMPLEMENTED | $7,085 | $1,340 |
$1,265
28,136
kWh
|
$5,820
-
MMBtu
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs