| Assessment Year | 1995 |
|---|---|
| Principal Product | furniture |
| NAICS |
n/a
|
| SIC | 2511: Wood Household Furniture, Except Upholstered |
| Sales Range | $10 M to 50M |
| # of Employees | 230 |
| Plant Area |
80,000
ft2
|
| Annual Production | 750,000
ton
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $154,020 | 2,806,858 |
kWh
|
$0.055 |
| Natural Gas | $9,728 | 2,070 |
MMBtu
|
$4.70 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $16,946 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,684 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,436 | $7,500 |
$8,436
87,339
kWh
|
|
| 02 | 2.7135: Install occupancy sensors | $498 | $450 |
$498
5,275
kWh
|
|
| 03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,737 | - |
$2,737
-
kWh
|
|
| 04 | 2.3135: Schedule routine maintenance during non-operating periods | $609 | - |
$609
-
kWh
|
|
| 05 | 2.6218: Turn off equipment when not in use | $2,102 | $1,000 |
$2,102
21,688
kWh
|
|
| 06 | 2.4221: Install compressor air intakes in coolest locations | $1,662 | $1,280 |
$1,662
17,292
kWh
|
|
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $902 | - |
$902
12,016
kWh
|
|
| TOTAL RECOMMENDED | $16,946 | $10,230 |
$16,946
143,610
kWh
|
||
| TOTAL IMPLEMENTED | $12,684 | $7,500 |
$12,684
99,355
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs