Assessment Year | 1994 |
---|---|
Principal Product | Plating of silver, gold, nickel, and tin |
NAICS |
n/a
|
SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
Sales Range | $5 M to 10M |
# of Employees | 50 |
Plant Area |
40,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $92,367 | 1,443,728 |
kWh
|
$0.064 |
Natural Gas | $35,325 | 7,295 |
MMBtu
|
$4.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,095 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,077 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.3312: Install efficient rectifiers | $17,153 | $28,400 |
$17,153
291,032
kWh
|
- | - | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $1,840 | $800 | - |
$1,840
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,325 | $1,973 |
$1,325
15,533
kWh
|
- | - | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $848 | $1,400 | - |
$848
-
MMBtu
|
- | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $229 | $500 | - |
$229
-
MMBtu
|
- | |
06 | 3.6112: Use filter and drying oven to reduce sludge volume | $9,700 | $38,000 | - | - |
$9,700
-
lb
|
|
TOTAL RECOMMENDED | $31,095 | $71,073 |
$18,478
306,565
kWh
|
$2,917
-
MMBtu
|
$9,700
-
lb
|
||
TOTAL IMPLEMENTED | $1,077 | $1,900 | - |
$1,077
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |