Assessment Year | 1997 |
---|---|
Principal Product | hydraulic hose assemblies |
NAICS |
n/a
|
SIC | 3492: Fluid Power Valves and Hose Fittings |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
30,000
ft2
|
Annual Production | 5,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $91,799 | 1,288,394 |
kWh
|
$0.071 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $102,663 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $96,254 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.441: Install automatic packing equipment | $90,000 | $30,000 | - | - | $90,000 | - | |
02 | 2.8121: Apply for tax-free status for energy purchases | $3,840 | $250 | - | - | - | $3,840 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,418 | $1,667 |
$2,418
33,998
kWh
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,096 | $125 |
$2,096
29,601
kWh
|
- | - | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $1,991 | $255 |
$1,991
28,136
kWh
|
- | - | - | |
06 | 2.7135: Install occupancy sensors | $1,120 | $856 |
$1,120
15,826
kWh
|
- | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $725 | $466 |
$725
10,258
kWh
|
- | - | - | |
08 | 3.5216: Recycle nonferrous dust | $473 | - | - |
$473
-
lb
|
- | - | |
TOTAL RECOMMENDED | $102,663 | $33,619 |
$8,350
117,819
kWh
|
$473
-
lb
|
$90,000 | $3,840 | ||
TOTAL IMPLEMENTED | $96,254 | $33,244 |
$6,254
88,218
kWh
|
- | $90,000 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs