Assessment Year 1994
Principal Product Corrugated cartons and point-of purchase displays
NAICS
n/a
SIC 2653: Corrugated and Solid Fiber Boxes
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area 245,000
ft2
Annual Production 780,000,000
thousand feet
Production Hrs. Annual 6,000
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $451,622 6,324,150
kWh
Natural Gas $244,205 72,809
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $54,206 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $20,860

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.3132: Recharge batteries on during off-peak demand periods $15,775 $23,025 $15,775
-
kWh
-
02 2.3135: Schedule routine maintenance during non-operating periods $7,285 - $7,285
-
kWh
-
03 2.2414: Use waste heat from hot flue gases to preheat $13,192 $32,000 - $13,192
-
MMBtu
04 2.1233: Analyze flue gas for proper air/fuel ratio $5,085 $500 - $5,085
-
MMBtu
05 2.7142: Utilize higher efficiency lamps and/or ballasts $6,164 $6,191 $6,164
86,460
kWh
-
06 2.7135: Install occupancy sensors $2,219 $1,125 $2,219
31,067
kWh
-
07 2.4221: Install compressor air intakes in coolest locations $2,673 $960 $2,673
37,515
kWh
-
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,264 $1,167 $1,264
17,585
kWh
-
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $549 - $549
4,982
kWh
-
TOTAL RECOMMENDED $54,206 $64,968 $35,929
177,609
kWh
$18,277
-
MMBtu
TOTAL IMPLEMENTED $20,860 $23,525 $15,775
-
kWh
$5,085
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs