Assessment Year 1994
Principal Product Pumps filters
NAICS
n/a
SIC 3561: Pumps and Pumping Equipment
Sales Range $10
M
to 50
M
# of Employees 92
Plant Area 70,000
ft2
Annual Production 50,000
pieces
Production Hrs. Annual 2,125
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $40,314 417,351
kWh
Natural Gas $20,688 4,307
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $10,220 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $6,216

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7447: Install vinyl strip / high speed / air curtain doors $2,341 $4,404 - $2,341
-
MMBtu
02 2.7142: Utilize higher efficiency lamps and/or ballasts $2,005 $3,657 $2,005
20,809
kWh
-
03 2.7134: Use photocell controls $1,159 $675 $1,159
12,016
kWh
-
04 2.7135: Install occupancy sensors $626 $225 $626
6,448
kWh
-
05 2.1233: Analyze flue gas for proper air/fuel ratio $1,512 $500 - $1,512
-
MMBtu
06 2.2437: Recover waste heat from equipment $303 $500 - $303
-
MMBtu
07 2.4324: Replace hydraulic / pneumatic equipment with electric equipment $490 $150 $490
4,982
kWh
-
08 2.1311: Replace electrically-operated equipment with fossil fuel equipment $245 $1,400 $312
3,224
kWh
$(-67.0)
-
MMBtu
09 2.3132: Recharge batteries on during off-peak demand periods $914 - $914
-
kWh
-
10 2.3131: Reschedule plant operations or reduce load to avoid peaks $346 - $346
-
kWh
-
11 2.4111: Utilize energy-efficient belts and other improved mechanisms $170 - $170
1,758
kWh
-
12 2.3131: Reschedule plant operations or reduce load to avoid peaks $109 - $109
-
kWh
-
TOTAL RECOMMENDED $10,220 $11,511 $6,131
49,237
kWh
$4,089
-
MMBtu
TOTAL IMPLEMENTED $6,216 $5,057 $4,704
39,273
kWh
$1,512
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs