ITAC Assessment: WI0186
ITAC logo
ITAC Assessment: WI0186
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1993
Principal Product Small Motors
NAICS
n/a
SIC 3694: Electrical Equipment for Internal Combustion Engines
Sales Range $10
M
to 50
M
# of Employees 407
Plant Area 150,000
ft2
Annual Production 0
units
Production Hrs. Annual 2,310
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $335,322 4,424,385
kWh
Natural Gas $40,129 12,025
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $33,475 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7252: Utilize an evaporative air pre-cooler or other heat exchanger in ac system $14,209 $15,000 n/a $14,209
247,655
kWh
-
02 2.7224: Reduce space conditioning during non-working hours $12,375 - n/a - $12,375
-
MMBtu
03 2.7142: Utilize higher efficiency lamps and/or ballasts $4,035 $10,375 n/a $4,035
53,341
kWh
-
04 2.7134: Use photocell controls $1,100 $525 n/a $1,100
14,654
kWh
-
05 2.7135: Install occupancy sensors $211 $372 n/a $211
2,931
kWh
-
06 2.1311: Replace electrically-operated equipment with fossil fuel equipment $567 $700 n/a $622
8,206
kWh
$(-55.0)
-
MMBtu
07 2.4221: Install compressor air intakes in coolest locations $353 $1,280 n/a $353
4,689
kWh
-
08 2.2437: Recover waste heat from equipment $303 $1,200 n/a - $303
-
MMBtu
09 2.6212: Turn off equipment during breaks, reduce operating time $322 $200 n/a $322
23,740
kWh
-
TOTAL RECOMMENDED $33,475 $29,652 $20,852
355,216
kWh
$12,623
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs