Assessment Year | 1993 |
---|---|
Principal Product | Die Castings |
NAICS |
n/a
|
SIC | 3363: Aluminum Die-Castings |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
70,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 5,000
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $453,062 | 6,050,117 |
kWh
|
$0.075 |
Natural Gas | $133,354 | 44,111 |
MMBtu
|
$3.02 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,588 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,642 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $4,627 | $8,250 |
$4,627
61,841
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,777 | $3,952 |
$1,777
23,740
kWh
|
|
03 | 2.7135: Install occupancy sensors | $1,425 | $225 |
$1,425
19,050
kWh
|
|
04 | 2.2511: Insulate bare equipment | $4,490 | $926 |
$4,490
77,667
kWh
|
|
05 | 2.7241: Install outside air damper / economizer on hvac unit | $1,440 | $2,800 |
$1,440
19,637
kWh
|
|
06 | 2.4221: Install compressor air intakes in coolest locations | $1,030 | $640 |
$1,030
13,775
kWh
|
|
07 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $637 | $225 |
$637
8,499
kWh
|
|
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $162 | - |
$162
2,052
kWh
|
|
TOTAL RECOMMENDED | $15,588 | $17,018 |
$15,588
226,261
kWh
|
||
TOTAL IMPLEMENTED | $4,642 | $6,977 |
$4,642
62,427
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs