| Assessment Year | 1993 |
|---|---|
| Principal Product | Die Castings |
| NAICS |
n/a
|
| SIC | 3363: Aluminum Die-Castings |
| Sales Range | $10 M to 50M |
| # of Employees | 160 |
| Plant Area |
70,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 5,000
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $453,062 | 6,050,117 |
kWh
|
$0.075 |
| Natural Gas | $133,354 | 44,111 |
MMBtu
|
$3.02 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,588 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,642 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $4,627 | $8,250 |
$4,627
61,841
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,777 | $3,952 |
$1,777
23,740
kWh
|
|
| 03 | 2.7135: Install occupancy sensors | $1,425 | $225 |
$1,425
19,050
kWh
|
|
| 04 | 2.2511: Insulate bare equipment | $4,490 | $926 |
$4,490
77,667
kWh
|
|
| 05 | 2.7241: Install outside air damper / economizer on hvac unit | $1,440 | $2,800 |
$1,440
19,637
kWh
|
|
| 06 | 2.4221: Install compressor air intakes in coolest locations | $1,030 | $640 |
$1,030
13,775
kWh
|
|
| 07 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $637 | $225 |
$637
8,499
kWh
|
|
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $162 | - |
$162
2,052
kWh
|
|
| TOTAL RECOMMENDED | $15,588 | $17,018 |
$15,588
226,261
kWh
|
||
| TOTAL IMPLEMENTED | $4,642 | $6,977 |
$4,642
62,427
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs