| Assessment Year | 1993 |
|---|---|
| Principal Product | Buttons, metal snappers etc. |
| NAICS |
n/a
|
| SIC | 3552: Textile Machinery |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
250,000
ft2
|
| Annual Production | 6,450,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $292,762 | 3,437,573 |
kWh
|
$0.085 |
| Natural Gas | $75,725 | 26,746 |
MMBtu
|
$2.83 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $72,352 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $43,605 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $17,501 | - | - |
$17,501
-
MMBtu
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,585 | $17,728 |
$12,585
147,714
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $9,793 | $3,450 |
$9,793
114,889
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,508 | $6,708 |
$2,508
29,601
kWh
|
- | |
| 05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $7,804 | $18,262 | - |
$7,804
-
MMBtu
|
|
| 06 | 2.2511: Insulate bare equipment | $2,007 | $51 |
$2,007
27,550
kWh
|
- | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,220 | - |
$4,220
49,531
kWh
|
- | |
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,009 | $1,067 |
$2,009
23,740
kWh
|
- | |
| 09 | 2.7241: Install outside air damper / economizer on hvac unit | $3,744 | $2,800 |
$3,744
43,962
kWh
|
- | |
| 10 | 2.3132: Recharge batteries on during off-peak demand periods | $3,494 | - |
$3,494
-
kWh
|
- | |
| 11 | 2.2414: Use waste heat from hot flue gases to preheat | $3,167 | $10,000 | - |
$3,167
-
MMBtu
|
|
| 12 | 2.1233: Analyze flue gas for proper air/fuel ratio | $498 | $500 | - |
$498
-
MMBtu
|
|
| 13 | 2.7243: Improve air circulation with destratification fans / other methods | $1,451 | $3,410 | - |
$1,451
-
MMBtu
|
|
| 14 | 2.7447: Install vinyl strip / high speed / air curtain doors | $841 | $900 | - |
$841
-
MMBtu
|
|
| 15 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $730 | $700 |
$849
9,965
kWh
|
$(-119.0)
-
MMBtu
|
|
| TOTAL RECOMMENDED | $72,352 | $65,576 |
$41,209
446,952
kWh
|
$31,143
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $43,605 | $28,971 |
$17,802
172,040
kWh
|
$25,803
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs