Assessment Year | 1992 |
---|---|
Principal Product | CORRUGATED PIPES |
NAICS |
n/a
|
SIC | 3317: Steel Pipe and Tubes |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 3,500
ton
|
Production Hrs. Annual | 2,375
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $16,787 | 262,896 |
kWh
|
$0.064 |
Natural Gas | $19,074 | 4,721 |
MMBtu
|
$4.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,598 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,356 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,686 | $1,850 |
$(-142.0)
(-2,345)
kWh
|
$2,828
-
MMBtu
|
- | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,224 | $500 | - |
$1,224
-
MMBtu
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,058 | $1,431 |
$1,058
16,706
kWh
|
- | - | |
04 | 2.8121: Apply for tax-free status for energy purchases | $498 | - |
$366
-
kWh
|
$132
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $132 | $646 |
$176
2,638
kWh
|
- | $(-44.0) | |
TOTAL RECOMMENDED | $5,598 | $4,427 |
$1,458
16,999
kWh
|
$4,184
-
MMBtu
|
$(-44.0) | ||
TOTAL IMPLEMENTED | $1,356 | $1,146 |
$176
2,638
kWh
|
$1,224
-
MMBtu
|
$(-44.0) |