Assessment Year 1992
Principal Product COOKIES AND CRACKERS
NAICS
n/a
SIC 2052: Cookies and Crackers
Sales Range $50
M
to 100
M
# of Employees 390
Plant Area
n/a
Annual Production 54,000,000
lb
Production Hrs. Annual 5,525
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $448,812 6,551,290
kWh
Natural Gas $234,555 89,318
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $22,983 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,068

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $4,588 - $5,420
79,132
kWh
- $(-832.0)
02 2.3132: Recharge batteries on during off-peak demand periods $6,926 $30,000 $6,926
-
kWh
- -
03 2.4221: Install compressor air intakes in coolest locations $3,906 $2,140 $3,906
55,686
kWh
- -
04 2.2525: Eliminate cooling of process streams which subsequently must be heated and vice versa $2,665 $200 $2,665
38,980
kWh
- -
05 2.1233: Analyze flue gas for proper air/fuel ratio $1,513 $500 - $1,513
-
MMBtu
-
06 2.7221: Lower temperature during the winter season and vice-versa $1,444 - - $1,444
-
MMBtu
-
07 2.7261: Install timers and/or thermostats $555 $400 - $555
-
MMBtu
-
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,386 $3,640 $1,386
20,223
kWh
- -
TOTAL RECOMMENDED $22,983 $36,880 $20,303
194,021
kWh
$3,512
-
MMBtu
$(-832.0)
TOTAL IMPLEMENTED $2,068 $900 - $2,068
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs