Assessment Year | 1990 |
---|---|
Principal Product | AUTOMOTIVE TIRES |
NAICS |
n/a
|
SIC | 3011: Tires and Inner Tubes |
Sales Range | $5 M to 10M |
# of Employees | 60 |
Plant Area |
n/a
|
Annual Production | 300,000
pieces
|
Production Hrs. Annual | 2,375
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $149,766 | 1,456,624 |
kWh
|
$0.10 |
Natural Gas | $65,912 | 18,666 |
MMBtu
|
$3.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $120,651 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,137 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3413: Burn fossil fuel to produce steam to drive a steam turbine-generator and use steam exhaust for heat | $77,488 | $400,000 |
$97,696
949,883
kWh
|
$(-20,208.0)
-
MMBtu
|
- | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $27,714 | - |
$29,139
-
kWh
|
- | $(-1,425.0) | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $8,473 | $3,895 |
$(-386.0)
(-3,810)
kWh
|
$8,859
-
MMBtu
|
- | |
04 | 2.3132: Recharge batteries on during off-peak demand periods | $5,068 | $800 |
$5,068
-
kWh
|
- | - | |
05 | 2.6121: Reduce hot water temperature to the minimum required | $563 | - |
$563
5,569
kWh
|
- | - | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $560 | $500 | - |
$560
-
MMBtu
|
- | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $449 | $1,744 |
$449
4,396
kWh
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $24 | $14 |
$24
586
kWh
|
- | - | |
09 | 2.6232: Install set-back timers | $160 | $400 |
$160
1,465
kWh
|
- | - | |
10 | 2.2511: Insulate bare equipment | $152 | $352 | - |
$152
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $120,651 | $407,705 |
$132,713
958,089
kWh
|
$(-10,637.0)
-
MMBtu
|
$(-1,425.0) | ||
TOTAL IMPLEMENTED | $15,137 | $6,953 |
$5,718
6,741
kWh
|
$9,419
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs