Assessment Year | 2015 |
---|---|
Principal Product | Propellers |
NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 260 |
Plant Area |
182,000
ft2
|
Annual Production | 200,000
units
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $383,295 | 8,164,550 |
kWh
|
$0.047 |
Electricity Demand | $268,829 | 17,436 |
kW-mo/yr
|
$15.42 |
Electricity Fees | $1,962 | - |
|
- |
Natural Gas | $121,482 | 22,752 |
MMBtu
|
$5.34 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,283 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,360 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,169 | - |
$752
16,494
kWh
|
$417
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 2.8112: Combine utility meters | $10,737 | - | - | - | $11,337 | - | - | - | $(-600.0) | |
03 | 3.4116: Meter recycled water (to reduce sewer charges) | $369 | $700 | - | - | - | - |
$369
-
Tgal
|
- | - | |
04 | 2.2437: Recover waste heat from equipment | $4,358 | $400 |
$(-624.0)
(-13,700)
kWh
|
$(-49.0)
-
kW-mo/yr
|
- |
$5,031
-
MMBtu
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,740 | $1,000 |
$1,940
42,569
kWh
|
$1,000
-
kW-mo/yr
|
- | - | - | $(-1,200.0) | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $164 | $375 |
$6
139
kWh
|
$158
-
kW-mo/yr
|
- | - | - | - | - | |
07 | 2.7135: Install occupancy sensors | $1,588 | $1,013 |
$1,238
27,169
kWh
|
- | - | - | - | $350 | - | |
08 | 2.7144: Install spectral reflectors / delamp | $1,699 | $315 |
$924
20,275
kWh
|
$512
-
kW-mo/yr
|
- | - | - | $263 | - | |
09 | 2.2514: Cover open tanks | $1,526 | $740 |
$999
21,924
kWh
|
$527
-
kW-mo/yr
|
- | - | - | - | - | |
10 | 2.2514: Cover open tanks | $612 | $600 |
$394
8,640
kWh
|
$218
-
kW-mo/yr
|
- | - | - | - | - | |
11 | 2.4323: Use optimum size and capacity equipment | $1,321 | $6,500 |
$850
18,650
kWh
|
$471
-
kW-mo/yr
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $25,283 | $11,643 |
$6,479
142,160
kWh
|
$3,254
-
kW-mo/yr
|
$11,337 |
$5,031
-
MMBtu
|
$369
-
Tgal
|
$(-587.0) | $(-600.0) | ||
TOTAL IMPLEMENTED | $6,360 | $2,703 |
$4,860
106,646
kWh
|
$2,087
-
kW-mo/yr
|
- | - | - | $(-587.0) | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs