Assessment Year 1990
Principal Product INDUSTRIAL ADHESIVES
NAICS
n/a
SIC 2891: Adhesives and Sealants
Sales Range $10
M
to 50
M
# of Employees 112
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 2,750
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $110,843 1,289,859
kWh
Natural Gas $78,483 20,186
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $13,454 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,888

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.3132: Recharge batteries on during off-peak demand periods $6,150 $800 $6,150
-
kWh
-
02 2.1233: Analyze flue gas for proper air/fuel ratio $2,481 $500 - $2,481
-
MMBtu
03 2.2414: Use waste heat from hot flue gases to preheat $2,027 $5,000 - $2,027
-
MMBtu
04 2.7447: Install vinyl strip / high speed / air curtain doors $1,539 $800 - $1,539
-
MMBtu
05 2.7142: Utilize higher efficiency lamps and/or ballasts $126 $1,929 $126
1,465
kWh
-
06 2.2136: Install / repair insulation on steam lines $249 $53 - $249
-
MMBtu
07 2.6121: Reduce hot water temperature to the minimum required $882 - $882
10,258
kWh
-
TOTAL RECOMMENDED $13,454 $9,082 $7,158
11,723
kWh
$6,296
-
MMBtu
TOTAL IMPLEMENTED $9,888 $3,282 $7,158
11,723
kWh
$2,730
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs