| Assessment Year | 1988 |
|---|---|
| Principal Product | SPRINGS, STAMPINGS,WIRE |
| NAICS |
n/a
|
| SIC | 3495: Wire Springs |
| Sales Range | $5 M to 10M |
| # of Employees | 43 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 2,375
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $47,488 | 681,125 |
kWh
|
$0.070 |
| Natural Gas | $11,297 | 2,304 |
MMBtu
|
$4.90 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $3,426 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,826 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4312: Improve lubrication practices | $1,042 | - |
$1,042
14,947
kWh
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $470 | - |
$470
6,741
kWh
|
|
| 03 | 2.3132: Recharge batteries on during off-peak demand periods | $1,213 | - |
$1,213
-
kWh
|
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $558 | $1,000 |
$558
7,913
kWh
|
|
| 05 | 2.6121: Reduce hot water temperature to the minimum required | $143 | - |
$143
2,052
kWh
|
|
| TOTAL RECOMMENDED | $3,426 | $1,000 |
$3,426
31,653
kWh
|
||
| TOTAL IMPLEMENTED | $1,826 | - |
$1,826
8,793
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs