Assessment Year | 1987 |
---|---|
Principal Product | EXPANDED METAL |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $121,272 | 1,242,087 |
kWh
|
$0.098 |
Natural Gas | $62,335 | 13,744 |
MMBtu
|
$4.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,858 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,741 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4312: Improve lubrication practices | $9,609 | - |
$9,609
98,476
kWh
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,160 | - |
$4,160
42,497
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $246 | $669 |
$246
2,638
kWh
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $1,335 | $2,000 |
$1,335
13,775
kWh
|
|
05 | 2.3191: Use demand controller or load shedder | $2,508 | $5,000 |
$2,508
-
kWh
|
|
TOTAL RECOMMENDED | $17,858 | $7,669 |
$17,858
157,386
kWh
|
||
TOTAL IMPLEMENTED | $5,741 | $2,669 |
$5,741
58,910
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs