| Assessment Year | 1987 |
|---|---|
| Principal Product | SHAPED WIRE |
| NAICS |
n/a
|
| SIC | 3315: Steel Wiredrawing and Steel Nails and Spikes |
| Sales Range | $10 M to 50M |
| # of Employees | 130 |
| Plant Area |
n/a
|
| Annual Production | 40,000,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $302,425 | 5,788,101 |
kWh
|
$0.052 |
| Natural Gas | $48,513 | 9,795 |
MMBtu
|
$4.95 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $45,783 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $20,108 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4312: Improve lubrication practices | $23,501 | - |
$23,501
449,883
kWh
|
- | - | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $13,151 | - |
$13,151
251,759
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,974 | $4,177 |
$5,974
114,302
kWh
|
- | - | |
| 04 | 2.6121: Reduce hot water temperature to the minimum required | $265 | - |
$265
-
kWh
|
- | - | |
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $983 | $500 | - |
$1,083
-
MMBtu
|
$(-100.0) | |
| 06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,909 | $750 | - |
$1,909
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $45,783 | $5,427 |
$42,891
815,944
kWh
|
$2,992
-
MMBtu
|
$(-100.0) | ||
| TOTAL IMPLEMENTED | $20,108 | $4,677 |
$19,125
366,061
kWh
|
$1,083
-
MMBtu
|
$(-100.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs