| Assessment Year | 2026 |
|---|---|
| Principal Product | Liquid and Gas Oxygen and Nitrogen |
| NAICS | 325120: Industrial Gas Manufacturing |
| SIC | 2813: Industrial Gases |
| Sales Range | $10 M to 50M |
| # of Employees | 30 |
| Plant Area |
280,000
ft2
|
| Annual Production | 9,120
ton
|
| Production Hrs. Annual | 7,300
hrs
|
| Location (State) | Alaska |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $950,986 | 8,107,200 |
kWh
|
$0.12 | |
| Electricity Demand | $494,286 | 15,481 |
kW-mo/yr
|
$31.93 | |
| Electricity Fees | $4,054 | - |
|
- | |
| Natural Gas | $95,099 | 8,482 |
MMBtu
|
$11.21 | |
| Waste Disposal Costs | |||||
| Solid Waste (non-haz) | $17,739 | 19,710 |
lb
|
$0.90 | |
| TOTAL YEARLY COSTS | $1,562,164 | ||||
| RECOMMENDED SAVINGS* | $269,571 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 4.651: Install back-up equipment | $172,619 | $196,087 | - | - | - | - | - | $172,619 | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $59,635 | $40,500 |
$57,491
490,122
kWh
|
$2,144
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $13,675 | $64,800 | - | - |
$13,675
-
MMBtu
|
- | - | - | |
| 04 | 2.7134: Use photocell controls | $795 | $1,729 |
$671
5,719
kWh
|
$125
-
kW-mo/yr
|
- | - | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,286 | $28,047 |
$4,035
34,485
kWh
|
$251
-
kW-mo/yr
|
- | - | - | - | |
| 06 | 2.4322: Use or replace with energy efficient substitutes | $18,560 | $100,800 | - | - | - |
$17,739
-
lb
|
$821 | - | |
| TOTAL RECOMMENDED | $269,571 | $431,962 |
$62,197
530,327
kWh
|
$2,520
-
kW-mo/yr
|
$13,675
-
MMBtu
|
$17,739
-
lb
|
$821 | $172,619 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Increase in Production Savings | |||