| Assessment Year | 2026 |
|---|---|
| Principal Product | Steel and aluminum castings |
| NAICS | 331511: Iron Foundries |
| SIC | 3321: Gray and Ductile Iron Foundries |
| Sales Range | $1 M to 5M |
| # of Employees | 32 |
| Plant Area |
36,000
ft2
|
| Annual Production | 660,000
pieces
|
| Production Hrs. Annual | 2,860
hrs
|
| Location (State) | Washington |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $105,934 | 1,270,896 |
kWh
|
$0.083 |
| Electricity Demand | $39,996 | 6,906 |
kW-mo/yr
|
$5.79 |
| Electricity Fees | $9,659 | - |
|
- |
| Natural Gas | $72,857 | 5,181 |
MMBtu
|
$14.06 |
| TOTAL YEARLY COSTS | $228,446 | |||
| RECOMMENDED SAVINGS* | $66,974 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,393 | $4,741 |
$1,131
13,558
kWh
|
$262
-
kW-mo/yr
|
|
| 02 | 2.1224: Replace boiler | $55,958 | $93,719 |
$55,958
670,956
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $1,640 | $7,378 |
$1,589
19,054
kWh
|
$51
-
kW-mo/yr
|
|
| 04 | 2.4226: Use / purchase optimum sized compressor | $7,983 | $32,480 |
$6,182
74,129
kWh
|
$1,801
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $66,974 | $138,318 |
$64,859
777,697
kWh
|
$2,114
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs