Assessment Year | 2023 |
---|---|
Principal Product | Heat Treated Metal |
NAICS | 332811: Metal Heat Treating |
SIC | 3398: Metal Heat Treating |
Sales Range | $1 M to 5M |
# of Employees | 16 |
Plant Area |
58,000
ft2
|
Annual Production | 30,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $240,887 | 2,765,633 |
kWh
|
$0.087 |
Electricity Demand | $80,474 | 10,965 |
kW-mo/yr
|
$7.34 |
Electricity Fees | $13,679 | - |
|
- |
Natural Gas | $104,566 | 10,649 |
MMBtu
|
$9.82 |
TOTAL YEARLY COSTS | $439,606 | |||
RECOMMENDED SAVINGS* | $112,073 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $74,176 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $705 | $2,080 |
$632
7,256
kWh
|
$73
-
kW-mo/yr
|
|
02 | 2.4226: Use / purchase optimum sized compressor | $73,471 | $88,000 |
$65,907
756,678
kWh
|
$7,565
-
kW-mo/yr
|
|
03 | 2.9114: Use solar heat to make electricty | $37,897 | $192,325 |
$33,980
390,123
kWh
|
$3,917
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $112,073 | $282,405 |
$100,518
1,154,057
kWh
|
$11,555
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $74,176 | $90,080 |
$66,539
763,934
kWh
|
$7,637
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs