Assessment Year | 2017 |
---|---|
Principal Product | potato chips, corn chips |
NAICS | 311919: Other Snack Food Manufacturing |
SIC | 2096: Potato Chips, Corn Chips, and Similar Snacks |
Sales Range | $100 M to 500M |
# of Employees | 150 |
Plant Area |
262,500
ft2
|
Annual Production | 240,000,000
units
|
Production Hrs. Annual | 8,712
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $347,181 | 9,266,641 |
kWh
|
$0.037 | |
Electricity Demand | $11,459 | 911 |
kW-mo/yr
|
$12.58 | |
Natural Gas | $111,838 | 33,585 |
MMBtu
|
$3.33 | |
Waste Disposal Costs | |||||
Water Usage | $217,419 | 87,669 |
Tgal
|
$2.48 | |
Water Disposal | $10,444 | 86,876 |
Tgal
|
$0.12 | |
Solid Waste (non-haz) | $285,313 | 2,296,500 |
lb
|
$0.12 | |
TOTAL YEARLY COSTS | $983,654 | ||||
RECOMMENDED SAVINGS* | $293,718 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $44,619 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.4131: Minimize contamination of water before treatment | $207,807 | $2,000,000 |
$(-34,369.0)
(-954,720)
kWh
|
$(-27,324.0)
-
kW-mo/yr
|
- | - | - | - |
$269,500
-
lb
|
|
02 | 3.4111: Use closed cycle process to minimize waste water production | $27,838 | $3,980 | - | - | - | - |
$26,499
-
Tgal
|
$1,339
-
Tgal
|
- | |
03 | 2.1224: Replace boiler | $26,315 | $176,427 | - | - | - |
$26,315
-
MMBtu
|
- | - | - | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $14,977 | $8,120 | - | - | - |
$14,977
-
MMBtu
|
- | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $10,358 | $90 |
$5,787
156,394
kWh
|
$3,472
-
kW-mo/yr
|
$1,099 | - | - | - | - | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $6,423 | $2,000 | - | - | - |
$6,423
-
MMBtu
|
- | - | - | |
TOTAL RECOMMENDED | $293,718 | $2,190,617 |
$(-28,582.0)
(-798,326)
kWh
|
$(-23,852.0)
-
kW-mo/yr
|
$1,099 |
$47,715
-
MMBtu
|
$26,499
-
Tgal
|
$1,339
-
Tgal
|
$269,500
-
lb
|
||
TOTAL IMPLEMENTED | $44,619 | $6,070 |
$5,787
156,394
kWh
|
$3,472
-
kW-mo/yr
|
$1,099 |
$6,423
-
MMBtu
|
$26,499
-
Tgal
|
$1,339
-
Tgal
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs