| Assessment Year | 2023 |
|---|---|
| Principal Product | Dry Pasta, Dough, and Flour Mixes Manufacturing from Purchased Flour |
| NAICS | 311824: Dry Pasta, Dough, and Flour Mixes Manufacturing from Purchased Flour |
| SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
| Sales Range | $500 k to 1M |
| # of Employees | 62 |
| Plant Area |
126,462
ft2
|
| Annual Production | 60,000
lb
|
| Production Hrs. Annual | 4,284
hrs
|
| Location (State) | Washington |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $74,938 | 920,229 |
kWh
|
$0.081 | |
| Electricity Demand | $23,567 | 5,443 |
kW-mo/yr
|
$4.33 | |
| Electricity Fees | $997 | - |
|
- | |
| Natural Gas | $5,090 | 432 |
MMBtu
|
$11.78 | |
| Waste Disposal Costs | |||||
| Solid Waste (non-haz) | $53,600 | 1,324,084 |
lb
|
$0.040 | |
| TOTAL YEARLY COSTS | $158,192 | ||||
| RECOMMENDED SAVINGS* | $8,423 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $687 | $1,488 |
$601
7,382
kWh
|
$86
-
kW-mo/yr
|
- | |
| 02 | 2.7135: Install occupancy sensors | $590 | $124 |
$590
7,242
kWh
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,161 | $624 |
$3,641
44,725
kWh
|
$520
-
kW-mo/yr
|
- | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $702 | $959 |
$611
7,507
kWh
|
$91
-
kW-mo/yr
|
- | |
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $199 | $282 |
$176
1,877
kWh
|
$23
-
kW-mo/yr
|
- | |
| 06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,084 | $5,025 | - | - |
$2,084
-
MMBtu
|
|
| TOTAL RECOMMENDED | $8,423 | $8,502 |
$5,619
68,733
kWh
|
$720
-
kW-mo/yr
|
$2,084
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs