Assessment Year | 2022 |
---|---|
Principal Product | Packaging Machinery Manufacturing |
NAICS | 333993: Packaging Machinery Manufacturing |
SIC | 3565: Packaging Machinery |
Sales Range | $50 M to 100M |
# of Employees | 105 |
Plant Area |
66,000
ft2
|
Annual Production | 500,000
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $136,425 | 2,250,126 |
kWh
|
$0.061 |
Electricity Demand | $43,644 | 6,948 |
kW-mo/yr
|
$6.28 |
Electricity Fees | $27,753 | - |
|
- |
Natural Gas | $22,648 | 2,010 |
MMBtu
|
$11.27 |
TOTAL YEARLY COSTS | $230,470 | |||
RECOMMENDED SAVINGS* | $2,964 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,637 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7224: Reduce space conditioning during non-working hours | $2,231 | - | - | - |
$2,231
-
MMBtu
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $405 | - |
$254
4,190
kWh
|
$152
-
kW-mo/yr
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $327 | $160 |
$205
3,379
kWh
|
$122
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $2,964 | $160 |
$459
7,568
kWh
|
$274
-
kW-mo/yr
|
$2,231
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,637 | - |
$254
4,190
kWh
|
$152
-
kW-mo/yr
|
$2,231
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs