Assessment Year 2010
Principal Product Track Link and Track Shoe Assemblies
NAICS 333120: Construction Machinery Manufacturing
SIC 3531: Construction Machinery and Equipment
Sales Range $10
M
to 50
M
# of Employees 290
Plant Area 210,000
ft2
Annual Production 1
units
Production Hrs. Annual 2,080
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $361,999 4,117,544
kWh
Electricity Demand $39,709 16,980
kW-mo/yr
Electricity Fees $18,480 -
Natural Gas $104,561 15,614
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $77,136 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.7145: Install skylights $9,511 $30,250 $8,149
97,594
kWh
$1,362
-
kW-mo/yr
- -
02 2.7135: Install occupancy sensors $3,119 $825 $2,931
35,100
kWh
$188
-
kW-mo/yr
- -
03 2.7111: Reduce illumination to minimum necessary levels $4,319 $170 $3,986
47,736
kWh
$333
-
kW-mo/yr
- -
04 2.4221: Install compressor air intakes in coolest locations $3,464 $1,500 $3,250
38,916
kWh
$214
-
kW-mo/yr
- -
05 2.4231: Reduce the pressure of compressed air to the minimum required $1,599 - $1,476
17,688
kWh
$123
-
kW-mo/yr
- -
06 2.4133: Use most efficient type of electric motors $1,109 $1,220 $1,023
12,261
kWh
$86
-
kW-mo/yr
- -
07 4.132: Purchase new equipment to reduce material use / cost $26,834 $15,000 - - - $26,834
08 2.7145: Install skylights $18,262 $9,040 $16,084
185,492
kWh
$2,178
-
kW-mo/yr
- -
09 2.7135: Install occupancy sensors $6,679 $3,600 $6,222
99,414
kWh
$457
-
kW-mo/yr
- -
10 2.7231: Use radiant heater for spot heating $2,240 $3,180 - - $2,240
-
MMBtu
-
TOTAL RECOMMENDED $77,136 $64,785 $43,121
534,201
kWh
$4,941
-
kW-mo/yr
$2,240
-
MMBtu
$26,834
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs