Assessment Year | 2010 |
---|---|
Principal Product | Track Link and Track Shoe Assemblies |
NAICS | 333120: Construction Machinery Manufacturing |
SIC | 3531: Construction Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 290 |
Plant Area |
210,000
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $361,999 | 4,117,544 |
kWh
|
$0.088 |
Electricity Demand | $39,709 | 16,980 |
kW-mo/yr
|
$2.34 |
Electricity Fees | $18,480 | - |
|
- |
Natural Gas | $104,561 | 15,614 |
MMBtu
|
$6.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $77,136 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7145: Install skylights | $9,511 | $30,250 |
$8,149
97,594
kWh
|
$1,362
-
kW-mo/yr
|
- | - | |
02 | 2.7135: Install occupancy sensors | $3,119 | $825 |
$2,931
35,100
kWh
|
$188
-
kW-mo/yr
|
- | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $4,319 | $170 |
$3,986
47,736
kWh
|
$333
-
kW-mo/yr
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $3,464 | $1,500 |
$3,250
38,916
kWh
|
$214
-
kW-mo/yr
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,599 | - |
$1,476
17,688
kWh
|
$123
-
kW-mo/yr
|
- | - | |
06 | 2.4133: Use most efficient type of electric motors | $1,109 | $1,220 |
$1,023
12,261
kWh
|
$86
-
kW-mo/yr
|
- | - | |
07 | 4.132: Purchase new equipment to reduce material use / cost | $26,834 | $15,000 | - | - | - | $26,834 | |
08 | 2.7145: Install skylights | $18,262 | $9,040 |
$16,084
185,492
kWh
|
$2,178
-
kW-mo/yr
|
- | - | |
09 | 2.7135: Install occupancy sensors | $6,679 | $3,600 |
$6,222
99,414
kWh
|
$457
-
kW-mo/yr
|
- | - | |
10 | 2.7231: Use radiant heater for spot heating | $2,240 | $3,180 | - | - |
$2,240
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $77,136 | $64,785 |
$43,121
534,201
kWh
|
$4,941
-
kW-mo/yr
|
$2,240
-
MMBtu
|
$26,834 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs