Assessment Year | 2022 |
---|---|
Principal Product | Aircraft Manufacturing |
NAICS | 336411: Aircraft Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 600 |
Plant Area |
89,784
ft2
|
Annual Production | 1,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $117,147 | 1,333,281 |
kWh
|
$0.088 |
Electricity Demand | $1,855 | 34 |
kW-mo/yr
|
$54.58 |
Electricity Fees | $5,756 | - |
|
- |
Natural Gas | $11,020 | 1,048 |
MMBtu
|
$10.52 |
TOTAL YEARLY COSTS | $135,778 | |||
RECOMMENDED SAVINGS* | $107,079 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,184 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2443: Re-use or recycle hot or cold process exhaust air | $6,178 | $7,000 | - | - |
$6,178
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,789 | $13,171 |
$4,474
50,901
kWh
|
$10,315
-
kW-mo/yr
|
- | |
03 | 2.7135: Install occupancy sensors | $11,216 | $1,580 |
$3,403
39,203
kWh
|
$7,813
-
kW-mo/yr
|
- | |
04 | 2.9114: Use solar heat to make electricty | $74,895 | $444,104 |
$74,895
852,045
kWh
|
- | - | |
TOTAL RECOMMENDED | $107,079 | $465,855 |
$82,772
942,149
kWh
|
$18,128
-
kW-mo/yr
|
$6,178
-
MMBtu
|
||
TOTAL IMPLEMENTED | $32,184 | $21,751 |
$7,877
90,104
kWh
|
$18,128
-
kW-mo/yr
|
$6,178
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs