| Assessment Year | 2010 |
|---|---|
| Principal Product | Cement |
| NAICS | 327310: Cement Manufacturing |
| SIC | 3241: Cement, Hydraulic |
| Sales Range | $50 M to 100M |
| # of Employees | 82 |
| Plant Area |
40,000
ft2
|
| Annual Production | 50,000
units
|
| Production Hrs. Annual | 7,896
hrs
|
| Location (State) | Washington |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $2,014,187 | 41,544,342 |
kWh
|
$0.048 |
| Electricity Demand | $103,077 | 116,504 |
kW-mo/yr
|
$0.88 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $752,837 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $24,225 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $702,459 | $5,700,000 |
$700,839
17,520,970
kWh
|
$1,620
-
kW-mo/yr
|
|
| 02 | 2.4224: Upgrade controls on compressors | $26,153 | $26,153 |
$26,153
653,828
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $24,225 | $81,585 |
$23,557
588,930
kWh
|
$668
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $752,837 | $5,807,738 |
$750,549
18,763,728
kWh
|
$2,288
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $24,225 | $81,585 |
$23,557
588,930
kWh
|
$668
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs