Assessment Year | 2020 |
---|---|
Principal Product | Wastewater |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
1,100,000
ft2
|
Annual Production | 3,650,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $500,963 | 7,774,795 |
kWh
|
$0.064 |
Electricity Demand | $201,736 | 16,192 |
kW-mo/yr
|
$12.46 |
TOTAL YEARLY COSTS | $702,699 | |||
RECOMMENDED SAVINGS* | $282,458 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $78,503 | $20 |
$62,056
963,600
kWh
|
$16,447
-
kW-mo/yr
|
|
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $199,826 | $110,000 |
$157,960
2,452,800
kWh
|
$41,866
-
kW-mo/yr
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,129 | $10,004 |
$3,014
46,799
kWh
|
$1,115
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $282,458 | $120,024 |
$223,030
3,463,199
kWh
|
$59,428
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs