Assessment Year | 2006 |
---|---|
Principal Product | Aluminum Extrude product |
NAICS | 331318: Other Aluminum Rolling, Drawing, and Extruding |
SIC | 3354: Aluminum Extruded Products |
Sales Range | $10 M to 50M |
# of Employees | 310 |
Plant Area |
260,000
ft2
|
Annual Production | 500
ton
|
Production Hrs. Annual | 4,832
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $126,191 | 1,356,356 |
kWh
|
$0.093 |
Electricity Demand | $43,893 | 6,079 |
kW-mo/yr
|
$7.22 |
Natural Gas | $69,293 | 13,990 |
MMBtu
|
$4.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,573 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,218 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2136: Install / repair insulation on steam lines | $8,070 | $3,858 | - | - | - |
$8,070
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,660 | $1,120 |
$4,320
78,350
kWh
|
$1,340
-
kW-mo/yr
|
- | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $3,950 | - |
$3,275
59,477
kWh
|
$675
-
kW-mo/yr
|
- | - | |
04 | 2.8121: Apply for tax-free status for energy purchases | $3,528 | - | - | - | $3,528 | - | |
05 | 2.2135: Repair and eliminate steam leaks | $2,600 | $1,820 | - | - | - |
$2,600
-
MMBtu
|
|
06 | 2.7492: Use proper thickness of insulation on building envelope | $1,900 | $685 |
$1,900
34,781
kWh
|
- | - | - | |
07 | 2.4314: Use synthetic lubricant | $455 | - |
$300
5,421
kWh
|
$155
-
kW-mo/yr
|
- | - | |
08 | 2.6218: Turn off equipment when not in use | $410 | - |
$410
7,450
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $26,573 | $7,483 |
$10,205
185,479
kWh
|
$2,170
-
kW-mo/yr
|
$3,528 |
$10,670
-
MMBtu
|
||
TOTAL IMPLEMENTED | $24,218 | $6,798 |
$8,005
145,277
kWh
|
$2,015
-
kW-mo/yr
|
$3,528 |
$10,670
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs