Assessment Year | 2007 |
---|---|
Principal Product | Gears and gear cutting |
NAICS | 333612: Speed Changer, Industrial High-Speed Drive, and Gear Manufacturing |
SIC | 3566: Speed Changers, Industrial High-Speed Drives, and Gears |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
120,000
ft2
|
Annual Production | 6,600
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $125,795 | 2,313,360 |
kWh
|
$0.054 |
Electricity Demand | $5,012 | 480 |
kW-mo/yr
|
$10.44 |
Electricity Fees | $3,453 | - |
|
- |
Natural Gas | $57,197 | 11,000 |
MMBtu
|
$5.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,857 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,144 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
---|---|---|---|---|---|---|---|
01 | 2.7444: Close holes and openings in building such as broken windows | $13,962 | $8,762 | - | - |
$13,962
-
MMBtu
|
|
02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $7,182 | $25,800 |
$6,865
147,001
kWh
|
$317
-
kW-mo/yr
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $3,351 | $5,595 |
$2,505
53,616
kWh
|
$846
-
kW-mo/yr
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,362 | $968 |
$1,362
29,165
kWh
|
- | - | |
TOTAL RECOMMENDED | $25,857 | $41,125 |
$10,732
229,782
kWh
|
$1,163
-
kW-mo/yr
|
$13,962
-
MMBtu
|
||
TOTAL IMPLEMENTED | $21,144 | $34,562 |
$6,865
147,001
kWh
|
$317
-
kW-mo/yr
|
$13,962
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs